1,399 bytes added
, 11:33, 27 February 2007
===Nut UPS – Uninterruptable Power Supply===
The primary goal of the Network UPS Tools (NUT) project is to provide reliable monitoring of UPS hardware and ensure safe shutdowns of the systems which are connected.
====Standard configuration====
Obtain your configuration values <br />
Find your model here http://www.networkupstools.org/compat/stable.html <br />
Type is only used if your model is genericups <br />
note. /dev/ttyS0 = com1, [[http://www.networkupstools.org/faq/ if using USB]] <br />
set configuration values
config setprop nut Device /dev/ttyS0
config setprop nut Model apcsmart
config setprop nut Type 7
config setprop nut status enabled
check
config show nut
apply changes and restart server
signal-event post-upgrade ; signal-event reboot
confirm server is communicating with UPS
upsc UPS@localhost
Emails are sent to admin whenever a UPS event occurs
====Configuring as a slave====
where 192.168.33.11 is your UPS master, the computer that will communicate with the UPS
The hostname of the server may also work.
set configuration values
config setprop nut SlaveUPS UPS@192.168.33.11
config setprop nut Master no
apply changes and restart server
signal-event post-upgrade ; signal-event reboot
confirm server is communicating with master
upsc UPS@192.168.33.11
====Conecting multiple UPS's====
to be added
http://bugs.contribs.org/show_bug.cgi?id=629