Changes

From SME Server
Jump to navigationJump to search
12 bytes added ,  21:38, 16 April 2021
no edit summary
Line 5: Line 5:  
'''A drive failure can corrupt an entire array: RAID does not replace backup!'''}}
 
'''A drive failure can corrupt an entire array: RAID does not replace backup!'''}}
   −
{{Note box| SME Servers Raid Options are largely automated, but even with the best laid plans things don't always go according to plan. See also: [[Raid:Manual Rebuild]], [[Raid:Growing]] and [[Hard Disk Partitioning]]. There is a wiki on the Linux software raid, you will find many [https://raid.wiki.kernel.org/index.php/Linux_Raid cool Tips here] }}
+
{{Note box| SME Servers RAID Options are largely automated, but even with the best laid plans things don't always go according to plan. See also: [[Raid:Manual Rebuild]], [[Raid:Growing]] and [[Hard Disk Partitioning]]. There is a wiki on the Linux software raid, you will find many [https://raid.wiki.kernel.org/index.php/Linux_Raid cool Tips here] }}
    
===Hard Drives===
 
===Hard Drives===
Line 346: Line 346:  
Login as root, type console. Select Item 5. "Manage disk reduncancy"
 
Login as root, type console. Select Item 5. "Manage disk reduncancy"
 
  <nowiki>--------Disk Reduncancy status as of Thursday Dec 22 -------
 
  <nowiki>--------Disk Reduncancy status as of Thursday Dec 22 -------
          Current RAID status:
+
            Current RAID status:
         
+
           
          Personalities : [raid1]
+
            Personalities : [raid1]
          md2 : active raid1 hda2[0] <-- NOTICE hdb2[#] is missing. Means hdb2[#] failed.
+
            md2 : active raid1 hda2[0] <-- NOTICE hdb2[#] is missing. Means hdb2[#] failed.
                                  38973568 blocks [2/1] [U_]
+
                                    38973568 blocks [2/1] [U_]
         
+
           
          md1 : active raid1 hda1[0] hdb1[1]
+
            md1 : active raid1 hda1[0] hdb1[1]
                104320 blocks [2/2] [UU]
+
                  104320 blocks [2/2] [UU]
         
+
           
          unused devices: <none>
+
            unused devices: <none>
          Only Some of the RAID devices are unclean.  <-- NOTICE This message and  
+
            Only Some of the RAID devices are unclean.  <-- NOTICE This message and  
          Manual intervention may be required.</nowiki> <-- this message.
+
            Manual intervention may be required.</nowiki> <-- this message.
 
Notice the last 2 sentences of the window above. You have some problems. <br>
 
Notice the last 2 sentences of the window above. You have some problems. <br>
 
If your system is healthy however the message you will see at the bottom of Raid Console window is:
 
If your system is healthy however the message you will see at the bottom of Raid Console window is: